Model .2500IAS Intelligent Actuator System
- Hydraulic
system controls.
- Multiple distance
function controls and checks all parameters of system operation and is the primary
control for all machine functions.
- Overall cycle time
monitors exactly how long it takes to make a complete part from initial start
to head retracted.
- Over process control alerts operator when
the system takes too long to make a completed assembly.
- Over
distance control alerts operator to excess travel of machine head.
- In-temperature
feature checks system prior to every cycle to assure proper operating temperature
and can be adjusted in 1 degree increments above and below temperature set point.
- True
system dwell time and freeze out cooling time destroy part memory and assure a
tight assembly.
- Machine setup menu allows operator to change
the operating mode of the system. Slide tables, freeze out cooling, part clamping
and part presence detecting can be turned on or off by a simple press of a button.
- Multiple job storage allows you to store operating parameters
for fast, easy machine setup.
- Multiple cycle counters, machine
overall cycle counter and re-settable day counter.
- Multi-zone
temperature control capable up to twelve zones standard, can be monitored and
changed remotely via a RS232 communication port.
|
|

|
|